1 · Micro-Melt® Biodur® CCM Plus® is a non-magnetic, cobalt-chromium-molybdenum alloy exhibiting high strength, corrosion resistance, and wear resistance. This alloy is a
contact2023319 · The P/M alloy has an ASTM grain size of 13.6 with an average grain dimension of 4.6µ and an average grain area of 22µ 2, as indicated in Figure 5. Figure 4.
contact2021211 · The graph for BioDur Carpenter CCM alloy is included for reference. Both alloys have similar maximum flow stress values for a given forging temperature. Each
contact2023320 · Biodur® CCM is a non-magnetic cobalt-chromium-molybdenum alloy exhibiting high strength with corrosion and wear resistance. The alloy is a high nitrogen,
contact2021211 · CarTech® BioDur® CCM® Alloy Page:3of9 € Poisson'sRatio€ 0.300 ModulusofElasticity(E)€ 35.0 x103 ksi ModulusofRigidity(G)€ 13.4 x103 ksi Typical
contact199551 · Abstract. BIODUR CCM PLUS ALLOY is a high carbon version of BioDur Carpenter CCM Alloy (Alloy Digest Co-96, March 1995), produced by vacuum induction
contact2023319 · NiTi alloys with optimized powder chemistry and print parameters exhibit superelastic and shape memory properties. none Biodur® 108 An essentially nickel-free
contact1 · Biodur® 108 is an essentially nickel-free austenitic stainless alloy with a high nitrogen content to maintain its austenitic structure. As a result, it has superior tensile
contact2023319 · Micro-Melt® Biodur CCM Low Nickel is a non-magnetic, cobalt-chromium-molybdenum wrought alloy exhibiting high strength, corrosion resistance, and wear
contactCarpenter BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1093°C 1 hr. Data provided by Carpenter Technology Corporation.Annealing followed by water quench and
contact20211222 · BioDur® CCM Plus® Alloy Annealed at 1093 ⁰C/1 h M7 Micro‐Melt® BioDur® Carpenter CCM® alloy Annealed at 1093 ⁰C/30 minutes M8 Carpenter MP35N Alloy 35 % deformed and aged at 538 ⁰C/4 h M9 Carpenter L‐605 Alloy Annealed at 1204⁰C M10 CP Titanium Grade 4 Annealed M11 Titanium Alloy Ti 6Al‐4V ELI Recrystallized
contact199551 · Abstract. BIODUR CCM PLUS ALLOY is a high carbon version of BioDur Carpenter CCM Alloy (Alloy Digest Co-96, March 1995), produced by vacuum induction melting, followed by inert gas atomization and hot isostatic pressure. Applications are in the orthopedic industry. This datasheet provides information on composition, physical
contact20131010 · MP35N(2), Alloy 2 (AMS 5842)(3), MP35N LTi 30 General structure BioDur Carpenter CCM®, BioDur CCM Plus® alloy 30 General structure. Note: Fresh sample needed. Should prepare one sample at a time. Use of Differential Interference Contrast (DIC) would help. Pyromet 625/Custom Age 625 PLUS® 26, 18, 19 General
contactCarpenter BioDur™ 316LS Stainless Medical Implant Alloy, 70% Cold Worked; Carpenter BioDur™ 316LS Stainless Medical Implant Alloy, 90% Cold Worked; Carpenter BioDur™ 316LS Stainless Medical Implant Alloy, Annealed; Carpenter BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1093°C 1 hr; Carpenter BioDur™ CCM Plus™ Medical Implant ...
contactBioDur™ Carpenter CCM® Medical Implant Alloy, Hot Worked; BioDur™ Carpenter CCM® Medical Implant Alloy, Warm Worked; BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1093°C 1 hr; BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1093°C 2 hr; BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1121°C 1 hr; BioDur™ CCM Plus ...
contactCarpenter Alloy 925 (UNS N09925) 25Ni-20Cr-6Mo Stainless (UNS N08925 N08926) Micro-Melt® CCW Alloy BioBlu 27 Alloy Micro-Melt® CCW Plus Alloy Duplex Alloy 2205 Pyromet® Alloy 617. Medical Alloys. MP35N Alloy BioDur® 108 Alloy BioDur® Type 316LS Stainless BioDur® Carpenter CCM® Alloy BioDur® CCM Plus® (Micro-Melt®) Alloy Pyromet ...
contact2023320 · This alloy is a powder metallurgy version of CarTech BioDur CCM alloy (ASTM F 1537 Alloy 1), which is a high nitrogen, low carbon wrought version of ASTM F 75 cast alloy. CarTech Micro-Melt BioDur Carpenter CCM alloy is produced by vacuum induction melting (VIM) followed by gas atomization and hot isostatic pressing to produce
contact2023319 · BioDur® 108 is an FDA approved, essentially nickel- and cobalt-free alternative to other stainless steel options and is currently used for medical applications such as implantable orthopedic devices, high-strength surgical instrumentation, and orthodontic devices. Typically, devices and instruments are produced via subtractive manufacturing ...
contactThis page has links to all data sheets in MatWeb for the tradename BioDur™. We have several search tools, listed above, that give you more efficient methods to reach the information that you need. BioDur™ has 15 material (s) in the MatWeb database. Back to Tradename List. Carpenter BioDur™ 316LS Stainless Medical Implant Alloy, 35% Cold ...
contact2017628 · Technical specifications of American high temperature alloys BioDur CCM Plus datasheet, BioDur CCM Plus Chemical compositions, BioDur CCM Plus mechanical properties from Steelmaking, ESR melted, Blooming, Forging, Hot rolling, Heat treatment, Straightening, Ultrasonic test, Cold working or Machined. ... Carpenter 20 Mo 6; AISI 660
contact20211222 · BioDur® CCM Plus® Alloy Annealed at 1093 ⁰C/1 h M7 Micro‐Melt® BioDur® Carpenter CCM® alloy Annealed at 1093 ⁰C/30 minutes M8 Carpenter MP35N Alloy 35 % deformed and aged at 538 ⁰C/4 h M9 Carpenter L‐605 Alloy Annealed at 1204⁰C M10 CP Titanium Grade 4 Annealed M11 Titanium Alloy Ti 6Al‐4V ELI Recrystallized
contact202323 · This alloy is a high carbon version of CarTech BioDur CCM alloy and meets the requirements of ASTM F1537, ASTM F799, ISO 5832-12 and ISO 5832-4. CarTech BioDur CCM Plus alloy is a wrought powder metallurgy product produced by vacuum induction melting (VIM) followed by gas atomization and hot isostatic pressing to produce
contact199551 · DURALCAN W2A.xxA-T6: Aluminum Alloy-Discontinuous Metal-Matrix Composite. ... BIODUR CCM PLUS ALLOY: Non Magnetic, Cobalt Chromium Molybdenum Alloy. Abstract . View article. PDF. CARLSON ALLOY 90 10 CuNi: Copper Nickel Alloy. Abstract . View article. PDF. MICROCAST-X MAR-M-247: High Temperature Nickel
contact201151 · A few of the most commonly used materials for implants are titanium, Ti-6Al-4V, stainless steels [Carpenter’s BioDur 316LS alloy], and cobalt alloys [BioDur CCM and BioDur CCM Plus alloys],” Guitterrez notes, “and those used for instruments are typically made from other classes of stainless steel [Project 70+, Custom 630, Custom 455 ...
contact20211215 · M5 BioDur® Carpenter . CCM® Alloy Annealed . M6 BioDur® CCM Plus® Alloy . Annealed at . 1093 ⁰ C/1 h . M7 Micro ‐ Melt® BioDur® Carpenter CCM® alloy . Annealed at . 1093 .
contact2017917 · BioDur CCM Plus . BioDur CCM--,,。. ,ASTM F75,ASTM F799, ASTM F1537, ISO 5832-4,5832-12。. BioDur CCM ...
contact. BioDur® Carpenter CCM® alloy is a non-magnetic cobalt-chromium-molybdenum alloy exhibiting high strength, corrosion resistance, and wear resistance. The alloy is a high nitrogen, low carbon wrought version of ASTM F75 Cast Alloy. BioDur Carpenter CCM alloy also meets the requirements of ASTM F799, ASTM F1537, ISO 5832-4 and ISO 5832-12.
contact199571 · Abstract. BioDur TrimRite Stainless has a composition that is balanced to be fully martensitic in the hardened condition. The alloy possesses a moderately high level of corrosion resistance and is applied as valve parts, guides, shafting and cutlery, including surgical tools. This datasheet provides information on composition, physical properties,
contact20211019 · Biodur® CCM® Alloy 1, Implant Quality. 인성과 연성, 내피로성, 내마모성, 높은 기계적 성질을 가지는 재료입니다. 주요 원소 Co + Cr + Mo 합금량이 98.5% 수준에 이르는 초합금입니다. 티타늄 합금, 니켈 base 합금과 함께 인체에 사용하며, 고관절 등, 관절 재료로 쓰입니다 ...
contact2023319 · BioDur® 108 is an FDA approved, essentially nickel- and cobalt-free alternative to other stainless steel options and is currently used for medical applications such as implantable orthopedic devices, high-strength surgical instrumentation, and orthodontic devices. Typically, devices and instruments are produced via subtractive manufacturing ...
contact199531 · Abstract. BIO-DUR CARPENTER CCM ALLOY is a high nitrogen, low carbon wrought version of ASTM F75 cast alloy and used in the orthopedic implant industry. This datasheet provides information on composition, physical properties, hardness, and tensile properties. It also includes information on forming, heat treating, and machining.
contact199551 · DURALCAN W2A.xxA-T6: Aluminum Alloy-Discontinuous Metal-Matrix Composite. ... BIODUR CCM PLUS ALLOY: Non Magnetic, Cobalt Chromium Molybdenum Alloy. Abstract . View article. PDF. CARLSON ALLOY 90 10 CuNi: Copper Nickel Alloy. Abstract . View article. PDF. MICROCAST-X MAR-M-247: High Temperature Nickel
contact20211215 · M5 BioDur® Carpenter . CCM® Alloy Annealed . M6 BioDur® CCM Plus® Alloy . Annealed at . 1093 ⁰ C/1 h . M7 Micro ‐ Melt® BioDur® Carpenter CCM® alloy . Annealed at . 1093 .
contactCarpenter BioDur™ CCM Plus™ Medical Implant Alloy, Hot Worked: 2: Carpenter BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1093°C 1 hr: 3: Carpenter BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1121°C 1 hr: 4: Carpenter BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1149°C (2100°F) 1 hr: 5: Carpenter BioDur™ CCM ...
contact202093 · BioDur® 108 (ASTM F2229, UNS S29108) is an essentially nickel- and cobalt-free stainless alloy used in FDA cleared designs for implantable medical devices and high strength surgical instruments. Its corrosion resistance, strength, fatigue, and non-magnetic properties are advantageous to the medical design community looking for alloy
contactSupplier of Biodur® CCM (CoCr28Mo / ISO 5832-12 / ASTM F1537 Alloy 1) alloy for medical, surgical and dental implants - precision ground rod and bar from stock. ... (CCM) alloy meets the strictest biocompatability and corrosion resistance requirements for the medical industry. It is produced by powder metallurgy which gives it an exceptionally ...
contactThis alloy is a high carbon version of BioDur Carpenter CCM® alloy and meets the requirements of ASTM F1537, ASTM F799, ISO 5832-12 and ISO 5832-4. BioDur CCM Plus alloy is a wrought powder metallurgy product produced by vacuum induction melting (VIM) followed by gas atomization and hot isostatic pressing to produce 100% dense billets.
contact. BioDur® Carpenter CCM® alloy is a non-magnetic cobalt-chromium-molybdenum alloy exhibiting high strength, corrosion resistance, and wear resistance. The alloy is a high nitrogen, low carbon wrought version of ASTM F75 Cast Alloy. BioDur Carpenter CCM alloy also meets the requirements of ASTM F799, ASTM F1537, ISO 5832-4 and ISO 5832-12.
contact199571 · Abstract. BioDur TrimRite Stainless has a composition that is balanced to be fully martensitic in the hardened condition. The alloy possesses a moderately high level of corrosion resistance and is applied as valve parts, guides, shafting and cutlery, including surgical tools. This datasheet provides information on composition, physical properties,
contactCarpenter BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1093°C 1 hr. Data provided by Carpenter Technology Corporation.Annealing followed by water quench and low stress grinding prior to tensile testing.Medical Implant Alloy. Non-magnetic Co-Cr-Mo alloy exhibiting high strength, corrosion resistance, and wear resistance.
contact